Method and validation

Detectability answers one question before fieldwork: will this method see this target? It models the response of the target along a profile across it, compares the result with the noise you can expect, and states every assumption behind the answer.

From target to verdict

  1. Forward model. The anomaly of the target is computed along a profile through its centre, from closed-form solutions (table below).
  2. Noise. Effective noise is the instrument noise and the field noise added in quadrature: σ = √(σinstrument² + σfield²).
  3. Signal-to-noise ratio. S/N = peak anomaly ÷ σ (for a step, the step amplitude).
  4. Verdict. S/N ≥ 5: clearly detectable; 2–5: marginal; below 2: not detectable. These are conventions, not physics, and are printed with every result.
  5. Station spacing. At least five stations across the anomaly width (full width at half maximum, or the 25–75 % width of a step), rounded down to 1, 2 or 5 × 10ⁿ m.
  6. Profile length. At least six times the depth to the top of the target and four times the anomaly width, so that the background on both sides is measured.

Main field and properties

Main field. The magnetic response depends on the direction and strength of the Earth's field at the survey site. Detectability computes it from the location and date with the 14th-generation International Geomagnetic Reference Field (IGRF-14), using the official IAGA coefficients.

Total-field anomaly. Magnetometers measure the total field; its anomaly is the projection of the anomalous field on the main-field direction, valid while the anomaly is much smaller than the main field. Magnetisation is induced (χF/μ₀) plus optional remanence; self-demagnetisation is neglected (χ ≪ 1).

Physical properties. Typical densities and magnetic susceptibilities, with their ranges, come from Telford, Geldart & Sheriff (1990), Tables 6.1 and 3.3. Natural values vary widely; enter measured contrasts when you have them.

Models

TargetGravityMagnetic
Sphere: cavity, boulder, buried objectPoint mass (exact outside the sphere)Point dipole
Horizontal cylinder: tunnel, pipe, galleryLine mass (2D)Line dipole (2D)
Rectangular prism: room, foundation, tankNagy (1966); Plouff (1976)Gravity gradient tensor (Nagy, Papp & Benedek 2000) and Poisson's relation
Vertical cylinder: shaft, wellSquare prism of equal cross-sectionSame
Dyke, wall, trench (any dip)Two vertical steps; dipping: 2D polygon (Talwani et al. 1959; Won & Bevis 1987)2D polygon, surface magnetic charge (Blakely 1996, ch. 9)
Vertical contact: fault, edge of a fillFaulted slab (Telford et al. 1990, §2.6)2D polygon

Instrument presets

Instrument noise is one standard deviation of a reading, taken from the manufacturer's data sheet (checked 4 November 2026). It is added in quadrature to the field noise, which usually dominates: the defaults are 10 µGal for gravity and 2 nT for magnetics, and both can be changed for your site.

PresetNoiseFigure in the data sheetSource
Scintrex CG-65 µGal repeatability, standard deviation < 5 µGalScintrex CG-6 Autograv
Scintrex CG-55 µGal standard deviation < 5 µGal (1 µGal resolution)Scintrex CG-5 Autograv
LaCoste & Romberg G20 µGal manufacturer's repeatability 10-20 µGal; the upper value is usedLaCoste & Romberg Model G
proton precession0.1 nT resolution and sensitivity 0.1 nTGeometrics G-856AX
Overhauser0.022 nT sensitivity 0.022 nT/√Hz, i.e. at 1 HzGEM Systems GSM-19 v7
caesium vapour0.008 nT noise < 0.008 nT/√Hz RMS, i.e. at 1 HzGeometrics G-858

Fluxgate gradiometers measure a vertical gradient rather than the total-field anomaly modelled here, so they are not offered yet.

Validation

The Validation page shows each comparison as a figure with its error. Every model is checked against a result computed in a different way. The library's automated test suite covers, among others:

Limitations

References